HoloMonitor App Suite Software
HoloMonitor® App Suite is a new proprietary software based on biological applications. Using App Suite, you can easily perform live-cell studies on various cellular events. The App Suite software has an intuitive user interface guiding the user through the simple step-by-step workflow, from the set-up of the experiment until the results are presented. HoloMonitor® App Suite is designed for automated and detailed analysis of cell populations. The automated analysis extracts selected cellular parameters that are condensed into quantitative application-specific output parameters.
This software includes all available applications but requires a license key for them to become activated and functional. License keys can be purchased here.
App Suite version: 3.5.1
Required OS: Microsoft Windows 10 (64-bit)
Download size: approx. 450 MB
Release Notes 3.5.1
New functionality
- In-Depth – Identify cells
- We have decreased the minimum allow value for Object size to enable segmenting very small cells or large viruses.
Bug fixes
-
- Experiment capture: We fixed an issue that could cause the software to crash or the experiment to stall while running an experiment. This bug was introduced in 3.5.0.
Release Notes 3.5.0
New functionality
- In-Depth – Wound healing
- The export has been upgraded to the xlsx-format including adding colors, styling and filters to all sheets.
- Graphs showing ‘Gap width (µm)’ and ‘Coverage area (%)’ has been added both the Wound Healing app and the Excel export.
- Analysis settings can now be applied to more than one frame at a time.
- Default vessel pattern is changed to ibidi’s vessel.
- In-Depth – Cell Morphology
- A major overhaul of the export has been made, including:
- Upgrading the export to the xlsx-format including adding colors, styling and filters to all sheets.
- Adding/removing/re-organizing data to make it more user-friendly.
- A major overhaul of the export has been made, including:
- In-Depth – Single Cell Tracking
- Included/excluded status, color and cell family number of tracked cells is now saved with the analysis.
- In-Depth – General
- A slider to improve contrast in the images has been added to the Image view in Cell morphology, Wound healing and Identify Cells.
- Live View
- Perspective parameters are added to the Frame view in the Images tab.
- Image analysis and Include/Exclude changes to any wells/position/frames now apply to all Controls that share the same well(s).
- Image Viewer
- We have added controls to only include a subset of frames when exporting video and images.
- General
- We have tested and confirmed that App Suite 3.5 is Windows 11 compatible.
- We have made a major overhaul of how treatment colors are shown in all exports.
- We have added the possibility to move the stage to the stage removal position from App Suite.
Bug fixes
-
- Motility export: Added a fix to avoid x-axes in the graphs sometimes being compressed.
- In-Depth General: Fixed sorting of Groups, e.g. to make 2 come before 10 etc.
- Image Capturing: Fixed an issue that happened for some high-end computers that uses a dedicated graphicscard, where the captured frame had pixels with unnaturally high intensities along the top border.
- Single cell tracking: Cell family tree graph did not display correctly for computers setup to use a 12-hour timesetting. This is now fixed.
- Single cell tracking: Fixed an error during export which made the export fail when more than 400 cell familieswas exported.
- Experiment summary: Fixed an issue that made the experiment storage size sometimes show a too large value.
Release Notes 3.4.0
New functionality
- The new Single Cell Tracking
Minor bug fixes & features
- Image viewers:
- Zoom in/out/reset and colour tool are now always visible.
- Capture setup / Live View:
- Minor layout update including making focus slider handle larger.
- Changed description of Reposition button.
- In-Depth -> Identify cells:
- GUI update in In-Depth -> Identify cells to match the identify functionality in the new Single Cell Tracking tool.
- Cell QC / Cell Count:
- Moved vessel map to under table in Cell QC.
- Added explanation to histograms in Cell QC and Cell Count how they are calculated.
- Flipped columns in Cell QC and Cell Count export to make it consistent with the software.
- Cell QC and Cell Count data (table, vessel and histograms) are now coloured according to treatment colour.
- Developer mode:
- Extended the software focus range to 0-2600 (from 300-2300).
- Guided assays: Edit experiment time & duration.
- Exports:
- Changed colours to mean and std. dev. columns in Proliferation export.
- Miscellaneous:
- Minor GUI update here and there.
- Fixed crash when saving colour-sets.
Release Notes 3.3.0
New functionality
- Option to copy the image analysis settings from an old result without being restricted to treatment or dose-response results.
- Added a cleaning guide in the hardware menu.
- Added a laser calibration wizard in the hardware menu.
- Added a “Reposition” button to the positions list in capture setup, that moves the selected position to the current camera position.
Release Notes 3.2.0
New functionality
- Option to copy image analysis settings from another result in the same experiment when creating a new one.
Bug fixes
- Image analysis page: Fixed an issue where applied changes sometimes did not save correctly.
Release Notes 3.1.0
New functionality
- Dose-response Analysis: Graph colors now correspond to conditions and dose colors.
- Motility and Proliferation Analysis: Graph colors now correspond to treatment colors.
- General:
- More responsive graphs when dealing with large datasets.
- Updated and consistent look & feel on all graphs.
- Image Analysis: Added ‘Selection’ as an option to copy sensitivity value to.
- M4 Hardware tool: Adjusted automatic XY stage calibration.